25 2024WINDING PROTECTION IS A KEY ISSUE WHEN USING GENERATOR SETS
Generator system:
•Anti-condensation space heaters
Alternators are of course affected by this issue, essentially due to their electromechanical nature,
since they contain numerous components that can fail prematurely. In addition to the mechanical
risk there is the risk of electrical malfunction.
The primary purpose ofgenerator setsis to provide electric current quickly and autonomously, in situations
and places where the main supply has failed. As a result, they are often faced with conditions of use
that do not provide an optimum environment. Extreme temperatures, humidity, dust, etc. All these
aggressors are likely to speed up ageing of the genset and its different components. Resistance to the weather and demanding conditions of use is therefore essential to ensure the longevity of a generator set.
In practice, we can see that for low-voltage machines excluding AVRs, the main sources of breakdown are divided evenly between the different alternator components.
DEMANDING ENVIRONMENTS
Environmental stress is usually classified according to four criteria:
•Humidity is a problem because it is an electrical conductor. It is therefore likely to encourage the development of
potential short-circuits. Moreover, moisture tends to accumulate in the bottom of the machine, where it mixes with dust
and does even more damage to the windings
Dust and other particlesconstitute another hazard, as they cause
mechanical abrasion of the varnish, which will gradually lead to a
deterioration in its performance. Since air circulation is used for cooling
inside the alternator, the presence of particles in the environment is
particularly harmful
Corrosion, especially rust due to a saline environment, is usually a factor in
the premature ageing of mechanical parts and windings. Alternators used
in coastal areas or in an unprotected marine environment are particularly
exposed to this risk. Corrosion can also cause the build-up of deposits
that may interfere with machine operation.
•In certain cases or for certain applications, generator sets can be used in environments saturated inchemicals which
pose a particularly high level of attack (acids, bases, alkali). Although this rarely happens, these situations must also be
taken into account
APPLICATIONS CONCERNED
Although it’s difficult to generalise, we can nonetheless draw up guidelines relating to the correlation between the
application for which an alternator is used, its environment and hence the required protection level.
The table below summarises these considerations.
For low voltage machines < 500 V, using a reinforced protection system leads to a power derating of about 6%.
OVERVIEW OF PROTECTION SYSTEMS
with performance and durability levels that can satisfy a particularly demanding specification. On the largest machines which will be used intensively (LSA 49/50), the exciter stator (field) is also covered in CW1081 two-part flexible epoxy resin.